for connection of up to 2 workshop machines (1 x 3~400 V and / or 1 x 1~230 V) in combination with up to 2 external suction devices (1 x 3~400 V and / or 1 x 1~230 V)
Function
when switching the workshop machine on, the suction device is also switched on automatically 2 – 3 seconds later
after the machine is switched off, the extraction system continues to run for approx. 3-4 seconds, so that the residual dust from the processing machine is extracted in accordance with the Hazardous Substances Ordinance
Technical data
Connected load min. 100 W, max. 400 V / 16 A / 11000 W
Power inlet: CEE 3 P+N+E / 16 A / 6 h with phase reverse
Outlets workshop machine: 1 x socket CEE 3 P+N+E / 16 A / 6 h, 1 x socket 2 P+E
Outlets suction device: 1 x socket CEE 3 P+N+E / 16 A / 6 h, 1 x socket 2 P+E
Connected load of all devices must never exceed the total of 16 A! The automatic start / stop module does not limit the starting current of a machine or device.